Parameters Required for Control Valve Sizing & Quotation

Views:266
Update time:2026-03-12

Process Conditions (Core)

  1. Service Medium
  • Medium: water, steam, air, natural gas, oil, acid, alkali, slurry, etc.
  • Particulate content, corrosiveness, crystallization tendency
  1. Temperature
  • Normal, maximum and minimum operating temperature
  1. Pressure
  • Normal operating pressure
  • Maximum inlet pressure P1
  • Outlet pressure P2
  • Pressure drop ΔP across valve
  1. Flow Rate
  • Normal, maximum and minimum flow rate
  • Unit: m³/h, t/h, kg/h, Nm³/h, etc.

Valve Body Parameters

  1. Nominal Diameter (DN)
  2. Pressure Class
  • PN16/PN25/PN40/PN63 or Class150/300/600
  1. Valve Body Material
  • WCB, 304, 316, 316L, Hastelloy, titanium, PTFE lined, rubber lined, etc.
  1. Trim Material (plug, seat, stem)
  • 304, 316, 316L, Stellite overlay, Hastelloy, etc.
  1. Packing
  • V-type PTFE, flexible graphite, stainless steel bellows, etc.
  1. Leakage Class
  • Class IV, V, VI (bubble-tight shutoff)

Structure & Flow Characteristic

  1. Valve Type
  • Globe single-seat, double-seat, cage, three-way, angle, butterfly, ball, diaphragm, etc.
  1. Flow Characteristic
  • Equal percentage / Linear / Quick opening
  1. Flow Direction
  • Flow open / Flow close
  1. Connection Type
  • Flanged, welded, threaded, clamped
  1. Special Requirements
  • Jacketed for heating / Cooling fin / Bellows seal
  1. Actuator
  2. Type
  • Pneumatic diaphragm / Pneumatic piston / Electric / Hydraulic
  1. Action Mode
  • Air-to-open (FO) / Air-to-close (FC)
  1. Air Supply Pressure
  • 4~0.6 MPa or others
  1. Explosion-proof Requirement
  • Ex d II CT4 / Ex ia, etc.

Accessories (Directly Affect Price)

  1. Valve Positioner (smart/mechanical)
  2. Solenoid Valve
  3. Filter Regulator
  4. Limit Switch (Feedback)
  5. Handwheel
  6. Lockup valve, booster, amplifier

Signal & Standards

  1. Control Signal
  • 4~20mA / HART / FF / Profibus
  1. Executive Standards
  • GB, HG, API, IEC, ANSI, etc.
  1. Material Certificate & Hydrostatic Test
  • Shell test, seal test
Related News
Read More >>
How to Mitigate Hydrogen Embrittlement in Valves: A Full-Spectrum Solution from Material Selection, Design to Operation & Maintenance
2026-11-12
Recommended audience: hydrogen energy, chemical industry, hydrogen refueling stations, coal chemical plants, pipeline O&M, equipment procurement Hydrogen is the energy of the future, but it can also be an invisible hazard to equipment. Under high-pressure hydrogen or hydrogen-containing service, valves are among the components most vulnerable to hydrogen embrittlement (HE). Many incidents do not come from overpressure. They come from …
Self-operated Temperature Control Valves: Working Principles of Heating Type & Cooling Type
2026-11-03
1. Basic Structure Overview The complete valve set consists of four key components: Temperature bulb (sensing probe): Immersed in the controlled medium to detect temperature, filled with temperature-sensing liquid inside; Capillary tube: Sealed pressure transmission line, transferring pressure generated by expansion or contraction inside the bulb to the actuator head; Actuator and spring assembly: The sensing pressure counteracts spring force …
Daily Maintenance Knowledge of Vortex Flowmeters
2026-10-25
Vortex flowmeters are widely used in petrochemical, new energy, power, metallurgy and other industries for measuring gas, steam and liquid flow. With advantages such as no moving parts, stable performance and wide measuring range, they are common flow measurement instruments on site. Good daily maintenance can effectively extend service life, reduce failure rate and ensure the accuracy of process measurement …
Principle of Electric Actuators
2026-10-15
Overview Electric actuators are terminal execution units in industrial process control systems. They receive standard control signals from control systems (DCS, PLC, regulators) and convert electrical signals into mechanical displacement or torque to drive regulating equipment such as valves and dampers. By doing so, they adjust process parameters including medium flow rate, pressure and liquid level to realize automatic regulation …

Leave Your Message