What are the advantages and characteristics of the Moore TCS temperature concentration system?

Views:273
Update time:2025-02-08

The TCM temperature acquisition module can receive 2-wire, 3-wire, or 4-wire heating resistors, thermocouples with various division numbers such as K, J, S, E, T, R, B, N, C, etc. It can also mix various types of inputs. For thermocouple measurement, TCM has a built-in cold junction compensation circuit; For special application scenarios, built-in linearization curves facilitate flexible user applications.

The protocol conversion module HMC has rich alarm functions, which can be easily and quickly configured through software setting of addresses and jumper free settings. After installation and operation, there is no need for maintenance, and the performance is stable, greatly reducing the maintenance workload of instrument personnel.

2.1 Save hardware, cable, and construction costs (see figure below)

The comparison between the left and right images above shows that after adopting the TCS temperature concentration system, there is no longer a need to configure specialized transmitters, long-distance cables, safety barriers, temperature receiving cards, etc. for each temperature point, greatly reducing investment costs; At the same time, it also reduces the amount of construction work required for laying cables.

2.2 Wide range input reduces the hassle of selecting and wiring

It can accept 2, 3, 4 wire Pt, Cu, Ni thermistors or 9 types of thermocouples (J, K, E, T, R, S, N, B, C), resistance (0-4000 ohms) and millivolt (50 to 1000mV) signal inputs, greatly reducing the additional selection and wiring work due to different temperature sensors,

2.3 Each input channel is independent of each other and has high stability

The temperature concentration module TCM adopts independent A/D converters for each input channel, and the channels do not affect each other, ensuring stable operation at each point. (As shown in the figure below)

2.4 Various input signals can be mixed freely to save backup resources

Due to the independence of input channels, it supports arbitrary mixed input of signals from different temperature sensors, thus avoiding the need to reserve backup ports for various different sensors.

2.5 Fast and accurate fault diagnosis function, shortening on-site service time

The HMC protocol conversion module has multiple fault detection functions, which can quickly provide diagnostic information for communication faults, temperature sensor disconnection, over limit, and power supply issues. It can also output relay signals as needed.

2.6 Communication protocol disclosure to avoid additional costs in the later stage

The on-site TCM temperature concentration module and indoor HMC protocol conversion module communicate using the publicly available HART protocol, without the need for dedicated cables, configuration tools, or professional service personnel, thus avoiding additional costs in the later stages.

2.7 Convenient configuration

It can be configured through three different methods: PC software, HART controller, or HART-232 converter.

2.8 Small size, saving control room cabinet space

The width of the protocol conversion module HMC is only 50mm, which is equivalent to the width of a mobile phone.

2.9 Suitable for hazardous environments

Related News
Read More >>
What is the selection of the Moore TCS temperature concentration system?
2025-02-08
Firstly, based on the number of user points, determine the number of sets to use TCS, whether to choose a one-to-one or a one-to-one two plan. Based on the specific number of points (it is recommended to leave two backup channels for one TCM temperature signal acquisition module), determine the number of TCM to be used.
What are the functions and components of the Moore TCS temperature concentration system?
2025-02-08
The TCS temperature concentration system “concentrates” up to 32 RTD and thermocouple signals through a pair of twisted pair cables, thereby significantly reducing measurement costs. The TCS temperature concentration system consists of one or two TCM temperature modules and one HMC protocol converter module. TCM can be installed in hazardous or safe areas, and HMC converts TCM’s HART data into …
What are the application scenarios for the Moore TCS temperature concentration system?
2025-02-08
The TCS temperature concentration system is applied in places where temperature points are relatively concentrated, such as heating furnaces, reactors, and other devices in oil refining units.

Leave Your Message