Pepperl+Fuchs Explosion-Proof Products
Explosion-proof products (safety barriers, signal conditioners)
Pepperl+Fuchs is a leading supplier of automation equipment in many industrial fields and has been associated with safety protection products in hazardous areas for decades. We have strong professional technical strength to provide customers in the process automation industry with a complete set of automation solutions.
Pepperl+Fuchs’ product portfolio includes isolated safety barriers, Zener safety barriers, signal conditioners, fieldbus devices, remote I/O devices, HART interface devices, level measurement devices, positive pressure explosion-proof equipment, HMI visual operation terminals for hazardous environments, customized explosion-proof boxes and junction boxes.
We provide the world’s manufacturing and processing industries with time-tested products and customized solutions for a variety of applications. Covering the oil and gas industry, petrochemical industry, chemical industry, pharmaceutical industry, as well as sewage treatment plants and power industry.
Intelligent transmitter input safety gate | KCD2-STC-EX1 | Single channel; used for two-wire intelligent transmitter and current source input; passive 4-20mA output; power consumption <1.7W; voltage: ≥15V |
Intelligent transmitter distribution appliances | KCD2-STC-1. SP. | Single-channel, intelligent transmitter distribution appliance, input 2-wire intelligent transmitter and two-wire intelligent current source, accuracy 0.1%, output passive 4-20mA |
Intelligent transmitter input safety gate | KCD2-STC-1.2O | Single channel, one-in and two-out, intelligent transmitter distribution, 2-wire transmitter 2-wire current source input, signal distributor, 4-20mA, accuracy 0.1% |
Intelligent transmitter input safety gate | KCD2-STC-EX1.2O | Single-channel; two-wire intelligent transmitter and two-wire intelligent current source; one-in and two-out, passive 4-20mA output; power consumption: 2.4W; voltage: ≥16 V |
Intelligent transmitter input safety gate | KCD2-STC-EX1 ES. | Single channel; used for two-wire intelligent transmitter and current source input; active 4-20mA output; power consumption <1.7W; Voltage: ≥15V. Reach SIL3 (IEC 61508) |
Intelligent current driver | KCD2-SCD-EX1 | Single channel; intelligent current drive; output load >650Ω; used for HART I/P and valve positioner; accuracy 0.1%, power consumption <0.8W |
Intelligent current driver | KCD2-SCD-1 | Single channel, intelligent current driver, output current load 800Ω, support HART, loop off-circuit monitoring, accuracy 0.1% |
Switching amplifier | KCD2-SR-EX2 | Dual-channel, relay output; output status can be selected, single knife double throw, loop monitoring, reach SIL2 (IEC 61508), 24VDC power supply |
Switch signal amplification safety gate | KCD2-SR-EX1 LB | Single-channel, dry contact or NAMUR standard signal input, one in and two out, relay output |
Switch signal amplification safety gate | KCD2-SOT-EX1 LB | Single-channel, dry contact or NAMUR standard signal input, one input and two output, transistor output |
Thermal resistance relay safety gate | KCD2-RR-EX1 | Single channel; two- and four-wire resistance and thermal resistance input (Pt100, PT500, PT1000); RTD output |
Thermal resistance relay safety gate | KCD2-RR2-EX1 | Single channel; three-wire resistance and thermal resistance input (Pt100, PT500, PT1000); RTD output |
Universal temperature transmission safety gate | KCD2-UT2-1 | Single-channel, general-purpose temperature transmitter, TC, thermal resistance input, output current 4-20mA |
Universal temperature transmission safety gate | KCD2-UT2-EX1 | Single channel; general-purpose temperature transmitter; RTD/TC input, active 4-20mA output |
Current relay signal regulator | KFD0-CS-1.50 | Single channel, current driver/repeator, current input/output 4-20mA, accuracy 0.1%, reach SIL2 (IEC 61508) |
Current driver/relay | KFD0-CS-2.50 | Dual channel, current driver/repeator, current input/output 4-20mA, accuracy 0.1%, REACH SIL2 (IEC 61508) |
Current alarm setting safety gate | KFD2-CRG2-EX1. Dimension | Single channel; 24 VDC power supply; alarm setter function; input of two-wire intelligent transmitter and intelligent current source, 2 relay outputs; power consumption: 1.7W; voltage: ≥17 V |
Redundant track power supply module with bus terminal | KFD2-EB2. R4A.B | Power distribution module, redundant configuration, external fuse, relay fault output/LED display |
Temperature conversion alarm setter | KFD2-GUT-1. Dimension | Single channel; general-purpose temperature transmission alarm setter; RTD/TC input, active 4-20mA output, relay output |
Temperature signal alarm setter | KFD2-GUT-EX1 Dimension | Single channel; general-purpose temperature transmission alarm setter; RTD/TC input, active 4-20mA output, relay output |
Intelligent current driver | KFD2-SCD2-2. LK | Dual channel, intelligent current driver, output current load 800Ω, support HART, loop circuit monitoring, accuracy 0.One percent |
Intelligent analog output safety gate | KFD2-SCD2-EX1 LK | Single channel; intelligent current drive; output load >650Ω; used for HART I / P and valve positioner; accuracy 0.1%, power consumption <2.7W |
Intelligent transmitter input safety gate | KFD2-STC5-EX2 | Dual-channel; input two-wire intelligent transmitter; passive output, power consumption <2.7W; voltage: ≥16V |
Switch signal amplification safety gate | KFD2-SR3-EX2.2S | Dual-channel, two-channel or one-in and two-out; dry contacts or NAMUR inputs can be used as signal distributors |
Switching amplifier | KFD2-SRA-Ex4 | 4-channel, dry contact or NAMUR input, relay output |
Solenoid valve drives safety fence | KFD0-SD2-EX1.1180 | Single channel, loop power supply, current limit 70 mA/9.9VDC; reach SIL3 (IEC 61508) |
Switch signal amplification safety gate | KFD2-SR2-EX1 W | Single channel, relay output, output state optional, single knife double throw, 24VDC power supply |
Intelligent transmitter input safety gate | KFD2-STC5-EX1 | Single channel; used for two-wire intelligent transmitter and current source input; active 4-20mA output; power consumption <1.7W; voltage: ≥15V |
Intelligent transmitter input safety gate | KFD2-STC5-1 | Single-channel, intelligent transmitter distribution, input 2-wire intelligent transmitter and two-wire intelligent current source, accuracy 0.1%, active output 4-20mA |
Intelligent transmitter input safety gate | KFD2-STC5-EX1.2O | Single-channel; two-wire intelligent transmitter and two-wire intelligent current source; one-in and two-out, passive 4-20mA output; power consumption: 2.4W; voltage: ≥16 V |
Signal converter with alarm function | KFD2-USC-1. Dimension | Single channel; signal converter… Input signal: 0… 20 mA, 0… 10 V / 0 … 60 Mv, output signal: 4-20mA |
Temperature conversion safety barrier | KFD2-UT2-EX2 | Dual-channel/single-channel one-in and two-out, general-purpose temperature transmitter, RTD/TC input, active 4-20mA output |
General-purpose frequency converter | KFD2-UFC-EX1. Dimension | Single channel, speed alarm, frequency transmission, NAMUR input, input 0-5KHZ, output 0/4 … 20mA, 1 relay output, 1 frequency output, 24VDC power supply |
Temperature conversion safety barrier | KFD2-UT2-EX1 | Single channel; general-purpose temperature transmitter; RTD/TC input, active 4-20mA output |
Temperature converter isolator | KFD2-UT2-2 | Dual-channel/single-channel one-in and two-out, general-purpose temperature transmitter, TC, thermal resistance input, output 4-20mA ULZ 000105 Voltage relay safety gate |
Voltage relay safety gate | KFD2-VR2-EX1.50M | Single channel; thermocouple, mV input/mV output; input voltage 0 mV…±50 mV; output voltage 0 mV…±50 mV |
Voltage relay safety gate | KFD2-VR4-EX1.26 | Single channel; voltage repeater…-20 – 0 V, vibration displacement monitoring signal |
Intelligent transmitter input safety gate | HiD2022 | Dual-channel, two-wire system: active 4-20mA output, up to SIL2 (IEC 61508) |
Intelligent transmitter input safety gate | HiC2025A | Single channel; used for two-wire intelligent transmitter and current source input; active 4-20mA output |
Intelligent transmitter input safety gate | HiC2025ES | Single channel; used for two-wire intelligent transmitter and current source input; active 4-20mA output; reach SIL3 (IEC 61508) |
Intelligent transmitter input safety gate | HiC2027 | Dual-channel/single-channel, two-wire system, one-in and two-out, active 4-20mA output; used for signal separators, reaching SIL2 (IEC 61508) |
Intelligent current-driven safety gate | HiC2031 | Single channel; intelligent current drive; output load >650Ω; used for HART I/P and valve positioner; accuracy 0.1%, power consumption <0.8W |
Temperature transmission safety gate | HiC2081 | Single channel, RTD or T/C input, output 4-20mA |
Switch signal amplification safety gate | HiC2822 | Dual channel, relay output |
Intelligent transmitter input safety gate | HiC2025 | Single channel; used for two-wire intelligent transmitter and current source input; passive 4-20mA output |
Switch signal amplification safety gate | HiC2841 | Single channel, switching quantity DI safety gate, transistor output ULZ 000138 Switch signal amplification safety gate |
Switch signal amplification safety gate | HiC2842 | Dual channel, switching quantity DI safety gate, transistor output |
Switch signal amplification safety gate | HiC2853 | Single-channel, fault-safe, transistor output; SIL3 (IEC 61508) |
Solenoid valve drives safety fence | HiC2873 | Single channel, loop power supply, current limit 70 mA/9.9VDC; reach SIL3 (IEC 61508) |
Solenoid valve drives safety fence | HiC2871 | Single channel, loop power supply, maximum current 45 mA/12VDC; reach SIL3 (IEC 61508) |
Current relay safety gate | HiD2036 | Dual channel, fire detector |
Intelligent current-driven safety gate | HiD2038 | Dual-channel; intelligent current drive; output load >650Ω; used for HART I/P and valve positioner; accuracy 0.1%, power consumption <2.7W |
Switch signal amplification safety gate | HiD2824 | Four-channel, four-way relay contact output, up to SIL2 (IEC 61508) |
Temperature transmission safety gate | HiD2082 | Dual-channel/single-channel one-in and two-out, RTD or T/C input, output 4-20mA |
Frequency signal conversion safety gate | HiD2891 | Single channel, speed alarm, frequency transmission, NAMUR input, input 0-5KHZ, output 0/4 … 20mA, 1 relay output, 24VDC power supply |
HiC series 8-slot safety fence universal bottom plate | HiCTB08-SCT-44C-SC-RA | 8-slot universal bottom plate, terminal in and terminal out |
HiC series 16-slot safety grid universal bottom plate | HiCTB16-SCT-44C-SC-RA | 16-slot universal bottom plate, terminal in and terminal out ULZ 000171 16-slot safety grid bottom plate (suitable for cross-river system) |
16-slot safety grid bottom plate (suitable for cross-river system) | HiCTB16-YC3-RRB-KS-CC-AI16 | 16-slot special bottom plate, single-channel AI |
16-slot safety grid bottom plate (suitable for cross-river system) | HiCTB16-YC3-RRB-KS-CC-AO16 | 16-slot dedicated bottom plate, single-channel AO |
32-slot safety grid bottom plate (suitable for Henghe system) | HiCTB32-YC3-RRB-AK-CC-DX32 | 32-slot dedicated bottom plate, single-channel DI |
16-slot safety fence bottom plate | MB-PF-126373 | 16-slot universal bottom plate, terminal out |
16-slot safety fence bottom plate (suitable for Honeywell system) | SC-GPCS-UNI16-PF | 16-slot dedicated base plate, single-channel AI/AO |
16-slot safety fence bottom plate (suitable for Honeywell system) | SC-GPCD-DI32-PF | 16-slot special bottom plate, single-channel DI |
Ziner-type safety fence | Z960 | Single channel, T/C, 6.5V/50 ohms |
Ziner-type safety fence | Z954 | Single channel, RTD, 0.6V/12 ohms |
Ziner-type safety fence | Z787 | Single channel, working voltage 26.5 V (10µ/300 ohms) |
Ziner-type safety fence | Z728.H | Single channel, working voltage 26.5 V (10µ/240 ohms) |
Ziner-type safety fence | Z787. H | Single channel, working voltage 26.5 V (10µ/240 ohms) |
General-purpose power supply rail | UPR-03. | 35mm DIN guide rail, support guide rail power supply, built-in 3 conductors, 2 meters long |
K&H series configuration cable | K-ADP-USB | Communication cable, USB interface, used for configuration temperature change and other products |
Cold-end compensation terminal (benan) | K-CJC-BU/ KC-CJC-1BU | Cold-end compensation terminal with temperature transmission isolation gate |