Pepperl+Fuchs Explosion-Proof Products

Explosion-proof products (safety barriers, signal conditioners) Pepperl+Fuchs is a leading supplier of automation equipment in many industrial fields and has been associated with safety protection products in hazardous areas for decades. We have strong professional technical strength to provide customers in the process automation industry with a complete set of automation solutions. Pepperl+Fuchs’ product portfolio includes isolated safety barriers, Zener …

Description

Explosion-proof products (safety barriers, signal conditioners)
Pepperl+Fuchs is a leading supplier of automation equipment in many industrial fields and has been associated with safety protection products in hazardous areas for decades. We have strong professional technical strength to provide customers in the process automation industry with a complete set of automation solutions.

Pepperl+Fuchs’ product portfolio includes isolated safety barriers, Zener safety barriers, signal conditioners, fieldbus devices, remote I/O devices, HART interface devices, level measurement devices, positive pressure explosion-proof equipment, HMI visual operation terminals for hazardous environments, customized explosion-proof boxes and junction boxes.

We provide the world’s manufacturing and processing industries with time-tested products and customized solutions for a variety of applications. Covering the oil and gas industry, petrochemical industry, chemical industry, pharmaceutical industry, as well as sewage treatment plants and power industry.

Intelligent transmitter input safety gate KCD2-STC-EX1 Single channel; used for two-wire intelligent transmitter and current source input; passive 4-20mA output; power consumption <1.7W; voltage: ≥15V
Intelligent transmitter distribution appliances KCD2-STC-1. SP. Single-channel, intelligent transmitter distribution appliance, input 2-wire intelligent transmitter and two-wire intelligent current source, accuracy 0.1%, output passive 4-20mA
Intelligent transmitter input safety gate KCD2-STC-1.2O Single channel, one-in and two-out, intelligent transmitter distribution, 2-wire transmitter 2-wire current source input, signal distributor, 4-20mA, accuracy 0.1%
Intelligent transmitter input safety gate KCD2-STC-EX1.2O Single-channel; two-wire intelligent transmitter and two-wire intelligent current source; one-in and two-out, passive 4-20mA output; power consumption: 2.4W; voltage: ≥16 V
Intelligent transmitter input safety gate KCD2-STC-EX1 ES. Single channel; used for two-wire intelligent transmitter and current source input; active 4-20mA output; power consumption <1.7W; Voltage: ≥15V. Reach SIL3 (IEC 61508)
Intelligent current driver KCD2-SCD-EX1 Single channel; intelligent current drive; output load >650Ω; used for HART I/P and valve positioner; accuracy 0.1%, power consumption <0.8W
Intelligent current driver KCD2-SCD-1 Single channel, intelligent current driver, output current load 800Ω, support HART, loop off-circuit monitoring, accuracy 0.1%
Switching amplifier KCD2-SR-EX2 Dual-channel, relay output; output status can be selected, single knife double throw, loop monitoring, reach SIL2 (IEC 61508), 24VDC power supply
Switch signal amplification safety gate KCD2-SR-EX1 LB Single-channel, dry contact or NAMUR standard signal input, one in and two out, relay output
Switch signal amplification safety gate KCD2-SOT-EX1 LB Single-channel, dry contact or NAMUR standard signal input, one input and two output, transistor output
Thermal resistance relay safety gate KCD2-RR-EX1 Single channel; two- and four-wire resistance and thermal resistance input (Pt100, PT500, PT1000); RTD output
Thermal resistance relay safety gate KCD2-RR2-EX1 Single channel; three-wire resistance and thermal resistance input (Pt100, PT500, PT1000); RTD output
Universal temperature transmission safety gate KCD2-UT2-1 Single-channel, general-purpose temperature transmitter, TC, thermal resistance input, output current 4-20mA
Universal temperature transmission safety gate KCD2-UT2-EX1 Single channel; general-purpose temperature transmitter; RTD/TC input, active 4-20mA output
Current relay signal regulator KFD0-CS-1.50 Single channel, current driver/repeator, current input/output 4-20mA, accuracy 0.1%, reach SIL2 (IEC 61508)
Current driver/relay KFD0-CS-2.50 Dual channel, current driver/repeator, current input/output 4-20mA, accuracy 0.1%, REACH SIL2 (IEC 61508)
Current alarm setting safety gate KFD2-CRG2-EX1. Dimension Single channel; 24 VDC power supply; alarm setter function; input of two-wire intelligent transmitter and intelligent current source, 2 relay outputs; power consumption: 1.7W; voltage: ≥17 V
Redundant track power supply module with bus terminal KFD2-EB2. R4A.B Power distribution module, redundant configuration, external fuse, relay fault output/LED display
Temperature conversion alarm setter KFD2-GUT-1. Dimension Single channel; general-purpose temperature transmission alarm setter; RTD/TC input, active 4-20mA output, relay output
Temperature signal alarm setter KFD2-GUT-EX1 Dimension Single channel; general-purpose temperature transmission alarm setter; RTD/TC input, active 4-20mA output, relay output
Intelligent current driver KFD2-SCD2-2. LK Dual channel, intelligent current driver, output current load 800Ω, support HART, loop circuit monitoring, accuracy 0.One percent
Intelligent analog output safety gate KFD2-SCD2-EX1 LK Single channel; intelligent current drive; output load >650Ω; used for HART I / P and valve positioner; accuracy 0.1%, power consumption <2.7W
Intelligent transmitter input safety gate KFD2-STC5-EX2 Dual-channel; input two-wire intelligent transmitter; passive output, power consumption <2.7W; voltage: ≥16V
Switch signal amplification safety gate KFD2-SR3-EX2.2S Dual-channel, two-channel or one-in and two-out; dry contacts or NAMUR inputs can be used as signal distributors
Switching amplifier KFD2-SRA-Ex4 4-channel, dry contact or NAMUR input, relay output
Solenoid valve drives safety fence KFD0-SD2-EX1.1180 Single channel, loop power supply, current limit 70 mA/9.9VDC; reach SIL3 (IEC 61508)
Switch signal amplification safety gate KFD2-SR2-EX1 W Single channel, relay output, output state optional, single knife double throw, 24VDC power supply
Intelligent transmitter input safety gate KFD2-STC5-EX1 Single channel; used for two-wire intelligent transmitter and current source input; active 4-20mA output; power consumption <1.7W; voltage: ≥15V
Intelligent transmitter input safety gate KFD2-STC5-1 Single-channel, intelligent transmitter distribution, input 2-wire intelligent transmitter and two-wire intelligent current source, accuracy 0.1%, active output 4-20mA
Intelligent transmitter input safety gate KFD2-STC5-EX1.2O Single-channel; two-wire intelligent transmitter and two-wire intelligent current source; one-in and two-out, passive 4-20mA output; power consumption: 2.4W; voltage: ≥16 V
Signal converter with alarm function KFD2-USC-1. Dimension Single channel; signal converter… Input signal: 0… 20 mA, 0… 10 V / 0 … 60 Mv, output signal: 4-20mA
Temperature conversion safety barrier KFD2-UT2-EX2 Dual-channel/single-channel one-in and two-out, general-purpose temperature transmitter, RTD/TC input, active 4-20mA output
General-purpose frequency converter KFD2-UFC-EX1. Dimension Single channel, speed alarm, frequency transmission, NAMUR input, input 0-5KHZ, output 0/4 … 20mA, 1 relay output, 1 frequency output, 24VDC power supply
Temperature conversion safety barrier KFD2-UT2-EX1 Single channel; general-purpose temperature transmitter; RTD/TC input, active 4-20mA output
Temperature converter isolator KFD2-UT2-2 Dual-channel/single-channel one-in and two-out, general-purpose temperature transmitter, TC, thermal resistance input, output 4-20mA ULZ 000105 Voltage relay safety gate
Voltage relay safety gate KFD2-VR2-EX1.50M Single channel; thermocouple, mV input/mV output; input voltage 0 mV…±50 mV; output voltage 0 mV…±50 mV
Voltage relay safety gate KFD2-VR4-EX1.26 Single channel; voltage repeater…-20 – 0 V, vibration displacement monitoring signal
Intelligent transmitter input safety gate HiD2022 Dual-channel, two-wire system: active 4-20mA output, up to SIL2 (IEC 61508)
Intelligent transmitter input safety gate HiC2025A Single channel; used for two-wire intelligent transmitter and current source input; active 4-20mA output
Intelligent transmitter input safety gate HiC2025ES Single channel; used for two-wire intelligent transmitter and current source input; active 4-20mA output; reach SIL3 (IEC 61508)
Intelligent transmitter input safety gate HiC2027 Dual-channel/single-channel, two-wire system, one-in and two-out, active 4-20mA output; used for signal separators, reaching SIL2 (IEC 61508)
Intelligent current-driven safety gate HiC2031 Single channel; intelligent current drive; output load >650Ω; used for HART I/P and valve positioner; accuracy 0.1%, power consumption <0.8W
Temperature transmission safety gate HiC2081 Single channel, RTD or T/C input, output 4-20mA
Switch signal amplification safety gate HiC2822 Dual channel, relay output
Intelligent transmitter input safety gate HiC2025 Single channel; used for two-wire intelligent transmitter and current source input; passive 4-20mA output
Switch signal amplification safety gate HiC2841 Single channel, switching quantity DI safety gate, transistor output ULZ 000138 Switch signal amplification safety gate
Switch signal amplification safety gate HiC2842 Dual channel, switching quantity DI safety gate, transistor output
Switch signal amplification safety gate HiC2853 Single-channel, fault-safe, transistor output; SIL3 (IEC 61508)
Solenoid valve drives safety fence HiC2873 Single channel, loop power supply, current limit 70 mA/9.9VDC; reach SIL3 (IEC 61508)
Solenoid valve drives safety fence HiC2871 Single channel, loop power supply, maximum current 45 mA/12VDC; reach SIL3 (IEC 61508)
Current relay safety gate HiD2036 Dual channel, fire detector
Intelligent current-driven safety gate HiD2038 Dual-channel; intelligent current drive; output load >650Ω; used for HART I/P and valve positioner; accuracy 0.1%, power consumption <2.7W
Switch signal amplification safety gate HiD2824 Four-channel, four-way relay contact output, up to SIL2 (IEC 61508)
Temperature transmission safety gate HiD2082 Dual-channel/single-channel one-in and two-out, RTD or T/C input, output 4-20mA
Frequency signal conversion safety gate HiD2891 Single channel, speed alarm, frequency transmission, NAMUR input, input 0-5KHZ, output 0/4 … 20mA, 1 relay output, 24VDC power supply
HiC series 8-slot safety fence universal bottom plate HiCTB08-SCT-44C-SC-RA 8-slot universal bottom plate, terminal in and terminal out
HiC series 16-slot safety grid universal bottom plate HiCTB16-SCT-44C-SC-RA 16-slot universal bottom plate, terminal in and terminal out ULZ 000171 16-slot safety grid bottom plate (suitable for cross-river system)
16-slot safety grid bottom plate (suitable for cross-river system) HiCTB16-YC3-RRB-KS-CC-AI16 16-slot special bottom plate, single-channel AI
16-slot safety grid bottom plate (suitable for cross-river system) HiCTB16-YC3-RRB-KS-CC-AO16 16-slot dedicated bottom plate, single-channel AO
32-slot safety grid bottom plate (suitable for Henghe system) HiCTB32-YC3-RRB-AK-CC-DX32 32-slot dedicated bottom plate, single-channel DI
16-slot safety fence bottom plate MB-PF-126373 16-slot universal bottom plate, terminal out
16-slot safety fence bottom plate (suitable for Honeywell system) SC-GPCS-UNI16-PF 16-slot dedicated base plate, single-channel AI/AO
16-slot safety fence bottom plate (suitable for Honeywell system) SC-GPCD-DI32-PF 16-slot special bottom plate, single-channel DI
Ziner-type safety fence Z960 Single channel, T/C, 6.5V/50 ohms
Ziner-type safety fence Z954 Single channel, RTD, 0.6V/12 ohms
Ziner-type safety fence Z787 Single channel, working voltage 26.5 V (10µ/300 ohms)
Ziner-type safety fence Z728.H Single channel, working voltage 26.5 V (10µ/240 ohms)
Ziner-type safety fence Z787. H Single channel, working voltage 26.5 V (10µ/240 ohms)
General-purpose power supply rail UPR-03. 35mm DIN guide rail, support guide rail power supply, built-in 3 conductors, 2 meters long
K&H series configuration cable K-ADP-USB Communication cable, USB interface, used for configuration temperature change and other products
Cold-end compensation terminal (benan) K-CJC-BU/ KC-CJC-1BU Cold-end compensation terminal with temperature transmission isolation gate

 

Leave Your Message


    Write your message here and send it to us.

    Leave Your Message